Products

GRP
Rooflights System

Lightweight rooflights that maximise natural daylight.

Thomas Panels & Profiles supplies GRP rooflights and translucent roofing sheets for agricultural, industrial and commercial buildings throughout the UK. Our fibreglass rooflights are designed to work alongside profiled roofing sheets, allowing natural daylight into buildings while maintaining a consistent roof profile.

Available in a wide selection of profiles, lengths and specifications, our GRP roofing sheets provide a practical daylighting solution for new buildings, extensions and roof refurbishment projects.

Key Advantages of GRP Rooflights

  • GRP rooflights are widely used within modern roof systems due to their practical and cost-effective benefits:
  • Natural Daylighting – Reduces reliance on artificial lighting, helping to lower energy consumption and improve working environments.
  • Lightweight Yet Strong – Easy to handle and install while providing excellent structural integrity.
  • Corrosion Resistant – Ideal for industrial or coastal environments where traditional materials may degrade.
  • Low Maintenance – Long service life with minimal upkeep required.
  • Weather and UV Resistant – Designed to withstand harsh UK weather conditions while maintaining performance.
  • Even Light Diffusion – Helps minimise glare and creates a more comfortable internal workspace.

GRP Rooflights

For Every Project

Our standard GRP rooflight sheets are supplied as standard Class 3, 8oz weight sheets, this Standard Stock Specification offers a reliable balance of strength, light transmission, and value, making it suitable for a wide range of general industrial and commercial roofing applications.

We understand that every project has different requirements. In addition to our standard Class 3, 8oz sheets, we can also supply alternative:

Classes and performance ratings

Heavier weight laminates

Specialist specifications such as mansafe and other safety-focused solutions

If you require a specific performance level or project-based specification, our team will be happy to discuss the best option for your application.

GRP rooflight INSTALLATION

GRP rooflights must be installed in accordance with project specifications, manufacturer guidance, and all relevant safety regulations.

Particular care must be taken during installation due to the fragile nature of the GRP material. The following fastener types and identification methods are to be used throughout the installation process.

1. Fragile Area Identification

Poppy red fasteners are used exclusively to identify sections of the roof where GRP rooflights are installed.

These fasteners act as a visual safety indicator to highlight fragile roof zones to installers and future maintenance personnel.

Operatives must avoid stepping directly onto GRP areas unless appropriate access equipment, crawl boards, or fall-protection measures are in place.

2. Sidelap Sealing – GRP to Steel Sheet

Grommet fasteners must be installed at all sidelap positions where the steel sheet overlaps the GRP rooflight.

The grommet provides a weatherproof seal, preventing water ingress at the interface between materials.

Fasteners should be installed perpendicular to the sheet profile, ensuring the sealing washer compresses evenly without deforming the GRP.

3. Overlap Stitching – GRP Over Steel

Where the GRP rooflight overlaps the steel sheeting, standard stitcher fasteners must be used.

Approved stitcher sizes include 16mm, 19mm, or 22mm, selected based on combined material thickness and project specification.

Stitchers should be installed at the required centres along the overlap to maintain sheet alignment and provide adequate wind uplift resistance.

4. Main Fixings to Structural Supports

29mm washer main fasteners are to be used when fixing the GRP rooflight through to the primary purlin or structural support.

The large washer distributes load evenly across the GRP surface, reducing the risk of cracking or stress fractures.

Care must be taken not to overtighten fasteners; compression should be sufficient to seal without causing indentation or damage to the rooflight.

5. General Installation Notes

Always pre-check sheet alignment before final tightening of fasteners.

Installers must ensure all fixings are square to the sheet surface to maintain weather integrity.

Cutting, drilling, or handling of GRP should be carried out using appropriate PPE due to fibre dust.

Any damaged rooflights or distorted fasteners must be replaced immediately.

AVAILABLE STOCK SIZES

GRP Stock Sizes (Class 3, 2.44kg)

The profiles and lengths shown below reflect our standard stock range; however, we can also supply a wider selection of profiles, lengths, and material classes to meet specific project requirements.
TPP1000-32TPP1000-30TPP1000-31TPP1000-34TPP1000-35TPP914-38TPP900-26TPP 14/3Profile 6Profile 3TPP1000-20Cape MonadDoubleSix MTrisomet 333
5ft5ft5ft5ft10ft10ft12ft5ft5ft10ft1.950mtr3.000m2.000m6.000m
6ft6ft6ft6ft12ft14ft6ft6ft3.750mtr3.050m
7ft8ft8ft6ft 3.8"14ft16ft7ft7ft5.550mtr
8ft10ft10ft7ft16ft8ft8ft6.096mtr
9ft12ft12ft8ft9ft8ft 6"
10ft14ft14ft9ft10ft9ft
11ft16ft16ft10ft12ft9ft 6"
12ft18ft18ft12ft14ft10ft
14ft20ft20ft14ft16ft12ft
16ft16ft18ft
18ft18ft20ft
20ft20ft

GRP Rooflights for Agricultural and Industrial Buildings

GRP rooflights are widely used in agricultural sheds, warehouses, factories, workshops and commercial buildings where natural daylight is required through the roof.

These translucent roofing sheets allow daylight to enter the building, helping create a brighter internal environment and reducing the need for artificial lighting during daylight hours.

Fibreglass rooflights can be incorporated into new roofing systems or used when replacing existing rooflight panels, provided the profile and specification are suitable for the building.

GRP Roofing Sheets to Match Steel Roof Profiles

Choosing the correct profile is important when installing GRP rooflights alongside metal roofing sheets.

Thomas Panels & Profiles supplies rooflights compatible with a wide range of roofing profiles, including TPP 1000-32, TPP 1000-30, TPP 1000-31, TPP 1000-34, TPP 914-38 and traditional corrugated profiles.

Matching the rooflight to the adjoining roof sheeting helps achieve the correct overlap arrangement and a consistent roof covering.

Our range includes standard stock sizes as well as additional profile and length options for specific project requirements.

Choosing the Right Fibreglass Rooflights

The appropriate GRP rooflight specification depends on the intended application, roof design and performance requirements.

Our standard stock range includes Class 3 rooflight sheets, with alternative material classes, heavier laminates and specialist safety-focused specifications available on request.

When selecting translucent roofing sheets, it is important to consider the required light transmission, roof profile, supporting structure and relevant safety requirements.

Rooflights should always be specified and installed in accordance with the applicable guidance for the roofing system.

GRP Rooflights for New Roofs and Refurbishment

Whether you’re constructing a new agricultural building or upgrading an existing industrial roof, GRP roofing sheets can be incorporated into a suitable profiled roofing system.

For refurbishment work, identifying the existing sheet profile is particularly important. The correct match helps ensure the replacement rooflights integrate properly with the surrounding roof covering.

Thomas Panels & Profiles can help customers identify suitable profile options and discuss available lengths and specifications.

Order GRP Rooflights from Thomas Panels & Profiles

We supply GRP rooflights alongside our range of steel roofing sheets, helping customers source compatible roofing materials for their projects.

Explore the available stock sizes and profiles above, or contact our team to discuss your requirements for fibreglass rooflights, translucent roofing sheets and specialist GRP specifications.

Technical Structural Sections Manual

Click below to get your copy of our major new release